Custom Communications Equipment Wiring Harnesses

Romtronic builds communications equipment wiring harnesses for the inside of telecom equipment: base station (RAN) cabinets, switch and router chassis, DC power distribution units and optical distribution frames (ODFs). When you send us a drawing or a sample, we build, label and test each harness to IPC/WHMA-A-620. Then we ship it ready to install.

IPC/WHMA-A-620 Class 2 or 3 · 100% electrical test · Prototypes in 5–15 business days · MOQ from 10 pcs

What are communications equipment wiring harnesses?

A harness is a pre-cut, pre-terminated bundle of power, RF, signal and grounding conductors with a label on every end. It replaces loose point-to-point wiring inside a cabinet or chassis. Because we test every circuit at the factory, your line installs the harness once instead of wiring and debugging by hand.

A wire harness is a branched assembly for the inside of an enclosure, while a cable assembly is usually one cable terminated at both ends. Most telecom builds need both, so we can supply them together.

Communications equipment wiring harnesses we build

TypeWhere it is used
RF coax jumper harnessRadio-to-antenna and filter jumpers in RAN and small-cell equipment
Backplane and card-edge harnessChassis backplane to daughter cards, I/O panel wiring
−48 V DC / PDU distribution harnessCabinet PDU to shelves and modules
Grounding and bonding harnessRack and frame grounding in central office and outdoor cabinets
Fiber breakout / ODF pigtail assemblyFan-out from fiber cable to connectorized pigtails
EMI-shielded I/O harnessControl and monitoring lines routed near RF or high-current power
BBU-to-RRU interconnect harnessCombined fiber, DC power and alarm conductors
Rack-to-rack interconnectPre-measured runs between cabinets
Alarm and environmental monitoring harnessTemperature, door and smoke sensor wiring

Our Custom-Made Wiring Harnesses for Communication Equipment

Each build started as a customer drawing or sample. If one looks close to what you need, tell us and we will quote from there. 

Outdoor Advertising Application Cable OM4 Optical Fiber+RJ45 Male +Tin to OM4 Optical Fiber+ RJ45 Male+ Ring Terminal+ JST VHR-3N Housing
Outdoor Advertising Application Cable OM4 Optical Fiber+RJ45 Male +Tin to OM4 Optical Fiber+ RJ45 Male+ Ring Terminal+ JST VHR-3N Housing
Schematic showing USB to TTL pinout and wiring for industrial microcontroller communication
Seamless Communication: Custom USB to TTL assemblies designed for stable data transmission in industrial environments.
D-Sub to BNC male adapter cable with rugged shielding for industrial test equipment.
D-Sub to BNC ruggedized high speed industrial signal interconnects
10-in-1 USB charging cable with multiple connectors (Mini USB, Micro-B, Proprietary pins) and reinforced splitter.
10-in-1 Universal USB Multi-Plug Charging Cable for Mobile Devices
M12 Male to D-Sub 9P Female + Banana Male2
M12 Male to D-Sub 9P Female + Banana Male2
Industrial chassis adapter cable with high-density DB and 19-pin USB connectors, low-interference shielded wiring, and full-coverage protective insulation.
Precision-engineered DB to USB interconnects for stable data bridging and compact chassis integration

RF coax jumper harness

Radio-to-antenna and filter jumpers for RAN and small-cell equipment. We fit SMA, N-type and 4.3-10 connectors and test VSWR. Low-PIM and phase-matched builds are available on request.

-48V DC PDU distribution harness with ring-lug terminations and heat-shrink labels
−48 V DC / PDU harnessHeavy-gauge feeders run from the cabinet PDU to shelves and modules, with ring or spade lugs and crimp pull tests.
Backplane and I/O panel wiring harness with D-sub and card-edge connectors
Backplane and I/O harnessChassis backplane to daughter cards and front-panel I/O, with shielded runs where needed.
Grounding and bonding harness with ring lugs for rack and frame grounding
Grounding and bonding harnessRack and frame bonding for central office and outdoor cabinets, cut to length and labeled.
Fiber breakout assembly fanning out to connectorized pigtails for an ODF
Fiber breakout and ODF pigtailsFan-out from fiber cable to connectorized pigtails, measured to your rack layout.

We also build EMI-shielded I/O harnesses, BBU-to-RRU interconnects, rack-to-rack trunks and alarm monitoring harnesses.

Key specifications

These specifications apply to our communications equipment wiring harnesses in general. However, we confirm the final values with you at drawing review.

ItemWhat we offer
ConductorsBare or tinned copper, stranded or solid
Wire size30 AWG signal wire up to heavy-gauge DC feeders
InsulationPVC, PE, XLPE or PTFE, matched to plenum, riser or general-purpose use
Voltage ratingUp to 600 V, depending on wire and connector ratings
ConnectorsJST, M8/M12/M16, D-sub, ring and spade lugs, RF (SMA, N-type, 4.3-10)
TerminationCrimp, solder or IDC, to IPC/WHMA-A-620 Class 2 or Class 3
RF assembliesVSWR-tested; low-PIM and phase-matched builds on request
ShieldingBraid or foil on EMI-sensitive lines
Temperature−40 °C to +105 °C, depending on the jacket
Materials complianceRoHS and REACH; UL-recognized materials on request
Prototype lead time5–15 business days
Production lead time2–4 weeks, depending on volume
MOQ10 pieces up to full production

How we keep communications equipment wiring harnesses consistent from sample to production

First, we review your drawing. An engineer checks pinout, wire gauge, connector part numbers, bend radius and routing, and sends back questions before cutting any wire.

Next, we build a first article for every program, whatever the order size. Once you approve it, it becomes the reference for production. After that, we inspect each unit after termination, after assembly and again at final QC.

TestWhat it checksApplied
ContinuityCorrect pin-to-pin connection, no opens or shorts100% of units
Insulation resistance / hipotInsulation integrity between conductors100% of units
TDRImpedance and fault location on controlled-impedance linesAs specified
Crimp pull forceMechanical strength of crimped terminalsSample basis, or as specified
Bend cycleFlex life of the cable and strain reliefQualification, or as specified
Technician running continuity and hipot tests on a telecom wiring harness at a bench test station

Engineering notes for telecom harnesses

−48 V DC feeders

Telecom equipment typically runs on a nominal −48 V DC supply, which ETSI EN 300 132-2 defines. For example, the Nokia 1830 ONE-m datasheet allows −40.5 V to −57 V at the input. Long or undersized feeders eat into that margin, so we check voltage drop at the drawing stage. You can also run your own numbers with our voltage drop calculator. In addition, we pull-test lug crimps on feeders, because a poor high-current joint runs hot.

RF jumpers

Passive intermodulation (PIM) depends heavily on workmanship. For example, Spinner’s 4.3-10 jumper data sheet lists a maximum IM3 figure for its own assembly, and the maker describes non-magnetic materials and fewer RF contact points as part of how it keeps PIM down. Therefore, we treat coupling torque and cleanliness as process steps. The 4.3-10 interface follows IEC 61169-54. If your system has a PIM limit, send us the target and test band, and we will confirm whether we can verify it.

Shielded I/O

Control and monitoring lines near RF or power conductors usually need shielding. However, the right shield termination depends on your grounding scheme, so we agree on it with you at drawing review.

Standards for communications equipment wiring harnesses

StandardHow it applies
IPC/WHMA-A-620 (current revision F)Workmanship and acceptance criteria for all harnesses. Class 2 covers sustained service; Class 3 covers critical or demanding use.
Telcordia GR-63-CORE / GR-1089-COREPhysical, EMC and electrical safety criteria for NEBS equipment. We build to the criteria you specify, while the end equipment carries the certification.
ETSI EN 300 132-2−48 V DC power interface, our reference when we size feeders.
ANSI/TIA-568Structured cabling that our patch and cross-connect harnesses connect to.
NFPA 262Flame and smoke test for plenum-rated cable. Specify it if harnesses run through air-handling spaces.
UL 444Covers premises communications cable. It does not govern internal −48 V power or RF harnesses.
RoHS (EU 2011/65/EU)For harnesses shipped to RoHS-regulated markets.

We confirm which standards apply during drawing review, and then they go into the build specification. You can also find our certificates on the certifications page.

Where these harnesses are used

Our communications equipment wiring harnesses go into these systems:

  • Telecom and data centers: base station cabinets, RRU and BBU cabling, networking racks
  • Central office racks, 5G small-cell and macro RAN equipment
  • Broadcast and satellite ground equipment
  • Industrial IoT gateways and rail signaling cabinets

Frequently asked questions

Which IPC class should I specify?

Class 2 suits most telecom equipment that must run reliably for years. Class 3 fits equipment where failure is unacceptable or the environment is severe. However, it costs more, so choose it only if your system needs it.

Can you copy an existing harness from a sample or an old drawing?

Yes. Send the sample or drawing, and we confirm pinout, wire gauge and connector part numbers with you before we cut any wire.

What is your minimum order?

We build as few as 10 pieces for low-volume, high-mix programs, and we scale up to full production volume.

Can you build communications equipment wiring harnesses to NEBS requirements?

We build to the GR-63-CORE and GR-1089-CORE criteria you give us. However, NEBS certification applies to the finished equipment, not to a harness alone.

Does UL 444 cover internal power or RF harnesses?

No. UL 444 covers premises communications cable. We build and test internal −48 V DC and RF harnesses to your equipment’s own electrical safety and EMC specifications.

Which connectors do you support?

We support JST, M8/M12/M16, D-sub, ring and spade lugs, and RF types including SMA, N-type and 4.3-10. Ask us if yours isn’t listed.

What should I send for a quote?

Send a wire list or schematic, connector part numbers, wire specs, quantity and required standards. If you have a reference sample, send that too. We then return a DFM review and quote within 24 hours.

Can you test PIM on RF jumpers?

Yes, in the frequency bands and to the limits you specify.